Wet Liquid Safety Glazing Methods for manufacturering laminated glass

Cast in place (CIP)
The edges of the glasses are taped using translucent double-sided adhesive tape. The tape retains the liquid and determines the thickness of the resin interlayer. The liquid resin is pumped, into the envelope, where it spreads evenly – even between irregular surfaces. All the air is removed out and corners and drilled holes are sealed with a translucent silicone to prevent the resin from escaping. The glass is put beneath UV lamps for approximately 20 minutes. CIP is ideal for curved and domed glass, where exceptional optical quality is required.